RS232c - Functional specs (9 typically used pins)
defines which circuits connect to each of 25 pins
9 pins used for typical modem configurations
20: Data Terminal Ready (DTE to DCE)
tells DCE that DTE is powered up and ready
6: Data Set Ready (DCE to DTE)
tells DTE that DCE is powered up and ready
8: Carrier Detect (DCE to DTE)
tells DTE that it detects a carrier on the (telephone) transmission line
4: Request to Send (DTE to DCE)
tells DCE it wants to send data (usually for half duplex)